top of page
Kuhnway banner_202505229-2.png

MD15~50C Normally Open Stainless Diaphragm Solenoid Valve

QUEEN SOLENOID VALVES

Discription

  • Suitable for air, inert gases, vacuum (10 Torr), water, kerosene oil, and oil (Below 50 cst).

  • Pilot operated, pressure range from 0.3kg*f/cm² to 10kg*f/cm².

  • Can be mounted in vertical and horizontal position.

  • The "M17" marking indicates a waterproof coil with an IP65 rating.

  • The diaphragm can be selected from NBR, EPDM, or Viton.

  • Material designation :

    • SCS13 : Stainless Steel 304

    • SCS14 : Stainless Steel 316

Specifications

Model

​​​​​​

​​

​​​

 ​(1) MD-15C-SCS13,14 (M17) 

​(2) MD-20C-SCS13,14 (M17)

​(3) MD-25C-SCS13,14 (M17)

(4) MD-32C-SCS13,14 (M17)

​(5) MD-40C-SCS13,14 (M17)

(6) MD-50C-SCS13,14 (M17)

Action mode

Normally open

Voltage

AC 24, 110, 220, 380V 50/60 Hz

DC 12, 24V​

Media

Air, vaccum, gas, water, oil

Fluid temp.

-5~90°C

Fluid viscosity

Oil : 50 cst or less

Pressure range

Air, water, gas : 0.3~10 kgf/cm2 

Oil : 0.3~7 kgf/cm2 

Connection size​​​

​​​

​(1) PT 1/2"    

​(2) PT 3/4"    

​(3) PT 1"       

(4) PT 1-1/4"

​(5) PT 1-1/2"

(6) PT 2"       

Orifice

 

 

(1) 16 mm​

(2) 23 mm

(3) 28 mm​

(4) 32 mm​​

(5) 40 mm​​

(6) 50 mm​

Cv valve

​​​​​

​​

​​​

 

(1)   3.7

(2)   6.3

(3)   8.0

(4) 13.0

(5) 20.3

(6)    32

Direction

Vertical / Horizontal

Valve material

S.S 304

S.S 316

Seal material

NBR

EPDM

​VITON

Coil type

Iron case coil: IP54

​Waterproof coil: IP65

Order Information

Seal Material Characteristics

• NBR

Temperature : -5~80°C

∙ Pros : Economical, widely used, with good oil and wear resistance.

∙ Cons : Unsuitable for polar solvents like nitro compounds, ozone, and ketones.

• EPDM

Temperature : -10~130°C

∙ Pros : Resistance to polar solvents (alcohols, ketones, ethylene glycol) and mild acids/bases.

∙ Cons : Not suitable for gasoline, mineral oil, and aromatic hydrocarbons.

• VITON (FPM/FKM)

Temperature : -10~120°C

∙ Pros : Stable, aging-resistant, and resistant to most oils and solvents.

∙ Cons : Costly, not recommended for ketones, esters, or nitro compounds.

Cautions

  • Before installation, please check whether the solenoid valve voltage is consistent with the power supply voltage.
    AC voltage tolerance: ±10%
    DC voltage tolerance: ±1%

  • If there are unclean impurities in the fluid, a filter should be installed to avoid reducing the service life and hindering the operation of the solenoid valve.

  • Please install the solenoid valve in the direction of the fluid.

  • Pilot-operated solenoid valves require a minimum pressure to open.

  • Not suitable for freezing fluids.

Certificate

  • CE

bottom of page