MD-P10~25 Pilot-operated Diaphragm Solenoid Valve

Discription

  • Pilot operated diaphragm solenoid valve, featuring high flow capacity and low power consumption (only 5.2 watts).

  • Suitable for Air, Inert gases, Water, Kerosene oil, Light oil (Below 50 cst).

  • Operating pressure range from 0.3 kgf/cm² ~ 16 kgf/cm², quick acting, durable usage.

  • Piping is simple and convenient, applicable to the upright pipe or a horizontal pipe connected unrestricted.

  • The "M10" marking indicates a waterproof coil with an IP65 rating.

  • The diaphragm can be selected from NBR, EPDM, or VITON.

QUEEN SOLENOID VALVES

Specifications

Model​​​​​

​​

(1) MD-P10WAG-M10

(2) MD-P15WAG-M10

(3) MD-P20WAG-M10

(4) MD-P25WAG-M10

Action mode

Normally closed

Voltage

AC 24, 110, 220, 380V 50/60Hz

DC 12, 24V​

Media

Air, gas, water, oil

Fluid temp.

-5~90°C

Fluid viscosity

Oil : 50 cst or less

Pressure range​​​​​

​​

Air, gas : 0.3~16 kgf/cm²

water : 0.5~16 kgf/cm²

Oil : 0.5~12 kgf/cm²

Connection size​​​

 

(1) PT 3/8"

(2) PT 1/2"

(3) PT 3/4"

(4) PT 1"   

Orifice​​​​

(1) 16 mm 

(2) 16 mm 

(3) 23 mm 

(4) 28 mm 

Cv valve​​​​

(1) 4.5 

(2) 4.5 

(3) 7.6 

(4) 9.6 

Direction

Vertical / Horizontal

Valve material

BSBF

Seal material

NBR

EPDM

VITON

Coil type

Waterproof coil: IP65

Seal Material Characteristics

• NBR

Temperature : -5~80°C

∙ Pros : Economical, widely used, with good oil and wear resistance.

∙ Cons : Unsuitable for polar solvents like nitro compounds, ozone, and ketones.

• EPDM

Temperature : -10~130°C

∙ Pros : Resistance to polar solvents (alcohols, ketones, ethylene glycol) and mild acids/bases.

∙ Cons : Not suitable for gasoline, mineral oil, and aromatic hydrocarbons.

• VITON (FPM/FKM)

Temperature : -10~120°C

∙ Pros : Stable, aging-resistant, and resistant to most oils and solvents.

∙ Cons : Costly, not recommended for ketones, esters, or nitro compounds.

Cautions

  • Before installation, please check whether the solenoid valve voltage is consistent with the power supply voltage.
    - AC voltage tolerance: ±10%
    - DC voltage tolerance: ±1%

  • If there are unclean impurities in the fluid, a filter should be installed to avoid reducing the service life and hindering the operation of the solenoid valve.

  • Please install the solenoid valve in the direction of the fluid.

  • Pilot-operated solenoid valves require a minimum pressure to open.

  • Not suitable for freezing fluids.

Certificate

  • CE

bottom of page