MD-P10~25 Pilot-operated Diaphragm Solenoid Valve
Discription
-
Pilot operated diaphragm solenoid valve, featuring high flow capacity and low power consumption (only 5.2 watts).
-
Suitable for Air, Inert gases, Water, Kerosene oil, Light oil (Below 50 cst).
-
Operating pressure range from 0.3 kgf/cm² ~ 16 kgf/cm², quick acting, durable usage.
-
Piping is simple and convenient, applicable to the upright pipe or a horizontal pipe connected unrestricted.
-
The "M10" marking indicates a waterproof coil with an IP65 rating.
-
The diaphragm can be selected from NBR, EPDM, or VITON.
QUEEN SOLENOID VALVES
Specifications
Model
(1) MD-P10WAG-M10
(2) MD-P15WAG-M10
(3) MD-P20WAG-M10
(4) MD-P25WAG-M10
Action mode
Normally closed
Voltage
AC 24, 110, 220, 380V 50/60Hz
DC 12, 24V
Media
Air, gas, water, oil
Fluid temp.
-5~90°C
Fluid viscosity
Oil : 50 cst or less
Pressure range
Air, gas : 0.3~16 kgf/cm²
water : 0.5~16 kgf/cm²
Oil : 0.5~12 kgf/cm²
Connection size
(1) PT 3/8"
(2) PT 1/2"
(3) PT 3/4"
(4) PT 1"
Orifice
(1) 16 mm
(2) 16 mm
(3) 23 mm
(4) 28 mm
Cv valve
(1) 4.5
(2) 4.5
(3) 7.6
(4) 9.6
Direction
Vertical / Horizontal
Valve material
BSBF
Seal material
NBR
EPDM
VITON
Coil type
Waterproof coil: IP65
Seal Material Characteristics
• NBR
∙ Temperature : -5~80°C
∙ Pros : Economical, widely used, with good oil and wear resistance.
∙ Cons : Unsuitable for polar solvents like nitro compounds, ozone, and ketones.
• EPDM
∙ Temperature : -10~130°C
∙ Pros : Resistance to polar solvents (alcohols, ketones, ethylene glycol) and mild acids/bases.
∙ Cons : Not suitable for gasoline, mineral oil, and aromatic hydrocarbons.
• VITON (FPM/FKM)
∙ Temperature : -10~120°C
∙ Pros : Stable, aging-resistant, and resistant to most oils and solvents.
∙ Cons : Costly, not recommended for ketones, esters, or nitro compounds.
Cautions
-
Before installation, please check whether the solenoid valve voltage is consistent with the power supply voltage.
- AC voltage tolerance: ±10%
- DC voltage tolerance: ±1% -
If there are unclean impurities in the fluid, a filter should be installed to avoid reducing the service life and hindering the operation of the solenoid valve.
-
Please install the solenoid valve in the direction of the fluid.
-
Pilot-operated solenoid valves require a minimum pressure to open.
-
Not suitable for freezing fluids.
Certificate
-
CE