MT15~50-BT Explosion-Proof Solenoid Valve – Threaded
QUEEN SOLENOID VALVES
Discription
Explosion-Proof Rating: Ex d IIB T3 Gb
Certificate No.: (ITRI) 2026 No. 07-00115X
The MT15~50-BT is a threaded explosion-proof solenoid valve with connection sizes from 1/2" to 2". It is available in either Normally Closed (NC) or Normally Open (NO) configurations and is suitable for various media, including steam, air, inert gases, water, and oil.
The internal sealing components can be supplied with Teflon (PTFE) material according to application requirements, making the valve suitable for high-temperature media such as steam. The maximum operating temperature can reach 200°C. The MT15~50-BT is suitable for industrial equipment and piping systems where explosion-proof protection is required.
Feature
-
Explosion-Proof Design: Explosion-proof rating Ex d IIB T3 Gb, suitable for industrial environments requiring explosion-proof protection.
-
Multiple Media Applications: Suitable for steam, air, inert gases, water, and oil with a viscosity of up to 50 cSt.
-
High-Temperature Application: Maximum operating temperature up to 200°C.
-
Flexible Installation: Can be installed in either vertical or horizontal orientation.
-
Multiple Pressure Ratings: Standard maximum operating pressure is 10 kgf/cm². 16 kgf/cm² or 20 kgf/cm² maximum operating pressure can also be customized upon request.
Specifications
Model
(1) MT-15BT (C)
(2) MT-20BT (C)
(3) MT-25BT (C)
(4) MT-32BT (C)
(5) MT-40BT (C)
(6) MT-50BT (C)
Action mode
Nor. Closed / Nor. Open
Voltage
AC 24, 110, 220, 380V 50/60Hz
DC 12, 24V
Media
Steam, air, inert gases, water, oil
Fluid temp.
-5~90°C (200°C)
Fluid viscosity
Oil : 50 cst or less
Pressure range
Steam, Water, Air: 0.3~10 kgf/cm2
Oil : 0.3~7 kgf/cm2
Connection size
(1) PT 1/2"
(2) PT 3/4"
(3) PT 1"
(4) PT 1-1/4"
(5) PT 1-1/2"
(6) PT 2"
Orifice
(1) 20 mm
(2) 20 mm
(3) 25 mm
(4) 32 mm
(5) 40 mm
(6) 50 mm
Cv valve
(1) 7.4
(2) 7.4
(3) 12.0
(4) 15.0
(5) 20.0
(6) 33.0
Direction
Vertical / Horizontal
Valve material
BC 6
Coil type
Explosion-Proof type
Order Information

Cautions
-
Before installation, please check whether the solenoid valve voltage is consistent with the power supply voltage.
- AC voltage tolerance: ±10%
- DC voltage tolerance: ±1% -
If there are unclean impurities in the fluid, a filter should be installed to avoid reducing the service life and hindering the operation of the solenoid valve.
-
Please install the solenoid valve in the direction of the fluid.
-
Pilot-operated solenoid valves require a minimum pressure to open.
-
Not suitable for freezing fluids.
Certificate
-
CE
-
(ITRI) 2026 No. 07-00115X